For the electrical isolation of RS-232 (V.24) interfaces, the PSM-ME-RS232/RS232-P is the ideal solution.
The RS-232 interface is an asymmetric voltage interface with common signal ground for all signals. In addition to its very low signal power, a characteristic feature of the interface is that the signal ground is connected to the grounded chassis housing. This results in very little immunity to interference and a maximum range of 15 meters. Using the PSM-ME-RS232/RS232-P Serial Isolator, considerably higher immunity to interference in industrial applications can be achieved.
By isolating the TX/RX data channels and the RTS/CTS control lines the PSM-ME-RS232 Serial Isolator effectively protects your RS232 devices from transient surges, lightning strikes, ground loops and noise issues.
For the electrical isolation of RS-232 (V.24) interfaces, the PSM-ME-RS232/RS232-P is the ideal solution.
The RS-232 interface is an asymmetric voltage interface with common signal ground for all signals. In addition to its very low signal power, a characteristic feature of the interface is that the signal ground is connected to the grounded chassis housing. This results in very little immunity to interference and a maximum range of 15 meters. Using the PSM-ME-RS232/RS232-P Serial Isolator, considerably higher immunity to interference in industrial applications can be achieved.
By isolating the TX/RX data channels and the RTS/CTS control lines the PSM-ME-RS232 Serial Isolator effectively protects your RS232 devices from transient surges, lightning strikes, ground loops and noise issues.
| Specifications | |
| 1 Year Return to Factory Warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8517.62.0020 UNSPSC Code: 43222608 ECCN: 5A991 | |
| Serial interface | |
| Interface 1 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1 | |
| Connection method D-SUB 9 plug | |
| Transmission length 15 m (shielded twisted pair) | |
| Conductor cross section solid min. 0.2 mm² | |
| Conductor cross section solid max. 2.5 mm² | |
| Conductor cross section AWG min. 24 | |
| Conductor cross section AWG max. 13 | |
| Pin assignment DTE/DCE switchover via switch | |
| Protocols supported transparent protocol | |
| Serial transmission speed 115.2 kbps | |
| Interface 2 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1 | |
| Connection method Pluggable screw connection | |
| Transmission length 15 m (shielded twisted pair) | |
| Conductor cross section flexible min. 0.2 mm² | |
| Conductor cross section AWG min. 24 | |
| Conductor cross section AWG max. 13 | |
| Ambient conditions | |
| Ambient temperature (operation) 0°C ... 55°C | |
| Ambient temperature (storage/transport) -40°C ... 85°C | |
| Permissible humidity (operation) 10 % ... 95 % (non-condensing) | |
| Altitude 5000 m (For restrictions see manufacturer's declaration) | |
| Degree of protection IP20 | |
| Noise immunity EN 61000-6-2:2005 | |
| General | |
| Electrical isolation VCC // V.24 (RS-232) (A) // V.24 (RS-232) (B) | |
| Test voltage data interface/power supply 2 kVrms (50 Hz, 1 min.) | |
| Standards and Regulations | |
| Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU | |
| Net weight 123.18 g | |
| Housing material PA | |
| Color green | |
| Conformance CE-compliant | |
| UL, USA/Canada 508 recognized | |
| Noise emission EN 61000-6-3 | |
| MTBF 2263 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 438 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| Transmission channels Transmission channels | |
| Bit delay <3 µs | |
| Bit distortion <5 % | |
| Test voltage data interfaces 2 kV AC | |
| Test voltage data interface/power supply 2 kV AC | |
| Power supply | |
| Nominal supply voltage 24 V AC/DC ±20 % | |
| Supply voltage range 19.2 V AC/DC ... 28.8 V AC/DC | |
| Typical current consumption 40 mA (24 V DC) | |
| Protective circuit Surge protection Suppressor diode | |
| Dimensions | |
| Width 22.5 mm | |
| Height 99 mm | |
| Depth 118.6 mm | |
| Environmental Product Compliance | |
| China RoHS Environmentally Friendly Use Period = 50 | |
| Standards and Regulations | |
| Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU | |
| EMC Immunity EN 61000-4-2: Contact discharge ± 6 kV (Test Level 3) EN 61000-4-3: Frequency range Test Level 3 EN 61000-4-4: Criterion B EN 61000-4-5: Signal ± 2 kV (12 Ω) EN 55011 EN 61000-4-6 | |
| Conformance CE-compliant | |
| UL, USA/Canada 508 recognized | |
| Noise emission EN 61000-6-3 | |
| Noise immunity EN 61000-6-2:2005 | |
| Connection in acc. with standard CUL | |
| UL, USA/Canada Class I, Div. 2, Groups A, B, C, D Class I, Zone 2, AEx nA IIC T4 Class I, Zone 2, Ex nA IIC T4 Gc X | |
| Approvals | |
| UL Recognized cUL Recognized DNV EAC cULus Recognized UL Listed cUL Listed cULus Listed | |
| Commercial data | |
| Packing unit 1 | |
| Weight per piece 181.2 g | |
| Country of origin Germany |