The PSI-MOS-RS232/FO 850 E Serial to Fiber Converter transparently connects RS232 devices to fiber optic cable. By transmitting RS232 data over optical fiber, these serial media converters provide an economical path to extend the reach of serial devices.
RS232 Serial transmission is limited to 20 Kbps over a distance of only 15 meters (50 feet). Using the FO 850 E Serial to Fiber Converter you can extend your serial data transmission up to 4.2km (2.6 miles). The result is that any two pieces of asynchronous serial equipment, located miles apart, can communicate at half or full duplex over fiber optic cable at rates up to 115.2 kbps.
Another advantage of the FO 850 E fiber optic transmission system is the electrically isolated connection of devices. Electromagnetic interference (EMI) is a common phenomenon in typical environments like industrial plants, warehouses and factory floors. This interference can cause corruption of data over RS232 or copper-based Ethernet links. Data transmitted over fiber optic cable however is completely immune to this type of noise, thus preventing the negative effects of voltage equalization currents and electromagnetic interference on the data cables. A Serial to Fiber Media Converter therefore enables you to inter-connect your serial devices over fiber ensuring optimal data transmission, increased availability of the system, and improved network design flexibility for point-to-point connections and star structures.
The PSI-MOS-RS232/FO 850 E Serial to Fiber Converter transparently connects RS232 devices to fiber optic cable. By transmitting RS232 data over optical fiber, these serial media converters provide an economical path to extend the reach of serial devices.
RS232 Serial transmission is limited to 20 Kbps over a distance of only 15 meters (50 feet). Using the FO 850 E Serial to Fiber Converter you can extend your serial data transmission up to 4.2km (2.6 miles). The result is that any two pieces of asynchronous serial equipment, located miles apart, can communicate at half or full duplex over fiber optic cable at rates up to 115.2 kbps.
Another advantage of the FO 850 E fiber optic transmission system is the electrically isolated connection of devices. Electromagnetic interference (EMI) is a common phenomenon in typical environments like industrial plants, warehouses and factory floors. This interference can cause corruption of data over RS232 or copper-based Ethernet links. Data transmitted over fiber optic cable however is completely immune to this type of noise, thus preventing the negative effects of voltage equalization currents and electromagnetic interference on the data cables. A Serial to Fiber Media Converter therefore enables you to inter-connect your serial devices over fiber ensuring optimal data transmission, increased availability of the system, and improved network design flexibility for point-to-point connections and star structures.
| Specifications | |
| 1 Year Return to Factory Warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8517.62.0020 UNSPSC Code: 43201500 ECCN: 5A991 | |
| Ambient conditions | |
| Ambient temperature (operation) -20°C ... 60°C | |
| Ambient temperature (storage/transport) -40°C ... 85°C | |
| Permissible humidity (operation) 30 % ... 95 % (non-condensing) | |
| Altitude 5000 m (For restrictions see manufacturer's declaration) | |
| Degree of protection IP20 | |
| Noise immunity EN 61000-6-2:2005 | |
| Standards and Regulations | |
| Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU | |
| Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 | |
| Test result 5g, 10-150 Hz, 2.5 h, in XYZ direction | |
| Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27 | |
| Test result 15g, 11 ms period, half-sine shock pulse | |
| Shock 15g in all directions in acc. with IEC 60068-2-27 | |
| Noise emission EN 55011 | |
| Noise immunity EN 61000-6-2:2005 | |
| Free from substances that could impair the application of coating according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard | |
| Connection in acc. with standard CUL | |
| Standards/regulations EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 | |
| Vibration (operation) In acc. with IEC 60068-2-6: 5g, 150 Hz | |
| Conformance CE-compliant | |
| ATEX II 3 G Ex nA nC IIC T4 Gc X II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) | |
| UL, USA/Canada Class I, Zone 2, AEx nc IIC T5 Class I, zone 2, Ex nC nL IIC T5 X Class I, Div. 2, Groups A, B, C, D | |
| Optical interface FO | |
| Number of FO ports 1 | |
| Transmit capacity, minimum -4.6 dBm (200/230 µm) -17.6 dBm (50/125 µm) -13.6 dBm (62,5/125 µm) | |
| Minimum receiver sensitivity -33.2 dBm | |
| Wavelength 850 nm | |
| Transmission length incl. 3 dB system reserve 2800 m (with F-K 200/230 8 dB/km with quick mounting connector) 4200 m (with F-G 50/125 2.5 dB/km) 4800 m (with F-G 62,5/125 3.0 dB/km) | |
| Transmission medium PCF fiber Multi-mode fiberglass | |
| Transmission protocol Transparent to protocol for RS-232 interface | |
| Connection method B-FOC (duplex ST®) | |
| General | |
| Transmission channels 2 (1/1), RxD, TxD, full duplex | |
| Bit distortion, input ± 35 % (permitted) | |
| Bit distortion, output < 6.25 % | |
| Electrical isolation VCC // V.24 (RS-232) | |
| Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.) | |
| Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU | |
| Noise emission EN 55011 | |
| Net weight 221.1 g | |
| Housing material PA 6.6-FR | |
| Color green | |
| MTBF 320 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 48 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| Conformance CE-compliant | |
| ATEX II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) | |
| UL, USA/Canada Class I, Zone 2, AEx nc IIC T5 Class I, zone 2, Ex nC nL IIC T5 X Class I, Div. 2, Groups A, B, C, D | |
| Digital outputs | |
| Output name Relay output | |
| Output description Alarm output | |
| Number of outputs 1 | |
| Maximum switching voltage 60 V DC 42 V AC | |
| Limiting continuous current 0.46 A | |
| Power supply | |
| Nominal supply voltage 24 V DC (With UL approval) | |
| Supply voltage range 18 V DC ... 30 V DC | |
| Max. current consumption 120 mA | |
| Typical current consumption 120 mA (24 V DC) | |
| Connection method COMBICON plug-in screw terminal block | |
| Serial interface | |
| Interface 1 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1 | |
| Connection method D-SUB 9 plug | |
| Transmission medium Copper | |
| Transmission length ≤ 15 m | |
| Conductor cross section solid min. 0.2 mm² | |
| Conductor cross section solid max. 2.5 mm² | |
| Conductor cross section flexible min. 0.2 mm² | |
| Conductor cross section flexible max. 2.5 mm² | |
| Conductor cross section AWG min. 24 | |
| Conductor cross section AWG max. 14 | |
| Serial transmission speed 115.2 kbps (NRZ) | |
| Dimensions | |
| Width 35 mm | |
| Height 99 mm | |
| Depth 105 mm | |
| Environmental Product Compliance | |
| China RoHS Environmentally Friendly Use Period = 50 | |
| Approvals | |
| cUL Listed cULus Listed UL Listed ATEX EAC DNV cUL Recognized cULus Recognized UL Recognized | |
| Commercial data | |
| Packing unit 1 | |
| Weight per piece 222.7 g | |
| Country of origin Germany | |
| Classifications | |
| eCl@ss 4.0 27230207 | |
| eCl@ss 4.1 27230207 | |
| eCl@ss 5.0 27230207 | |
| eCl@ss 5.1 27230207 | |
| eCl@ss 6.0 27230207 | |
| eCl@ss 7.0 27230207 | |
| eCl@ss 8.0 19179290 | |
| eCl@ss 9.0 19179290 | |
| ETIM 2.0 EC001423 | |
| ETIM 3.0 EC001423 | |
| ETIM 4.0 EC001423 | |
| ETIM 5.0 EC000310 | |
| ETIM 6.0 EC000310 | |
| UNSPSC 6.01 30211506 | |
| UNSPSC 7.0901 39121008 | |
| UNSPSC 11 39121008 | |
| UNSPSC 12.01 39121008 | |
| UNSPSC 13.2 43222604 |