Ethernet patch panels make the connection between field cabling and control cabinet cabling quick and easy. In environments vulnerable to voltage surges, aPP-RJ-F DIN Rail Patch Panelis ideal for installation inside control panels and distribution cabinets whereone-to-one simplified connectionsneed to be made in environments. A standard Ethernet patch cable is used between the patch panel and the control cabinet equipment, such as switches, PLCs and routers. Through ICD, Push-in, Screw or RJ45 connectors, field wiring is easily connected to the patch panel and protected inside a covered wiring space. The cable shielding is connected quickly and easily, without tools, while simultaneously ensuring strain relief. This simplifies installation of the field cable and saves a great deal of time during installation. PP-RJ DIN Rail Patch Panels provide the perfect mix of density and flexibility to decrease network risk and improve cable organization in scalable deployments with constricted spaces.
The cable shield current monitoring can be used for diagnostics. An LED indicates if there are differences in potential or other shield currents caused by EMC.
For greater flexibility and time savings during installation you can choose between IDC, Push-in, Screw, and RJ45 connections.
Ethernet patch panels make the connection between field cabling and control cabinet cabling quick and easy. In environments vulnerable to voltage surges, aPP-RJ-F DIN Rail Patch Panelis ideal for installation inside control panels and distribution cabinets whereone-to-one simplified connectionsneed to be made in environments. A standard Ethernet patch cable is used between the patch panel and the control cabinet equipment, such as switches, PLCs and routers. Through ICD, Push-in, Screw or RJ45 connectors, field wiring is easily connected to the patch panel and protected inside a covered wiring space. The cable shielding is connected quickly and easily, without tools, while simultaneously ensuring strain relief. This simplifies installation of the field cable and saves a great deal of time during installation. PP-RJ DIN Rail Patch Panels provide the perfect mix of density and flexibility to decrease network risk and improve cable organization in scalable deployments with constricted spaces.
The cable shield current monitoring can be used for diagnostics. An LED indicates if there are differences in potential or other shield currents caused by EMC.
For greater flexibility and time savings during installation you can choose between IDC, Push-in, Screw, and RJ45 connections.
| Specifications | |
| 1 Year Return to Factory Warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8536.90.8085 UNSPSC Code: 43223309 ECCN: EAR99 | |
| Serial interface | |
| Interface 1 Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u | |
| Connection method PP-RJ-RJ-F 27030208 RJ45 socket PP-RJ-SC-F 27030218 Screw terminal block PP-RJ-SCC-F 27030228 Push-in connection PP-RJ-IDC-F 27030238 IDC connection | |
| Transmission length 100 m (including patch cables) | |
| Pin assignment 1:1 | |
| Serial transmission speed 10/100/1000 Mbps | |
| Maximum output current 725 mA (PoE) | |
| Current carrying capacity ≤ 1.5 A (≤ 60 W (PoE+)) | |
| Maximum output power 60 W | |
| Interface 2 Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u | |
| Connection method RJ45 CAT5e | |
| Conductor cross section solid min. PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 0.14 mm² PP-RJ-SCC-F 27030228 0.2 mm² PP-RJ-IDC-F 27030238 0.14 mm² | |
| Conductor cross section solid max. PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 1.5 mm² PP-RJ-SCC-F 27030228 1.5 mm² PP-RJ-IDC-F 27030238 0.34 mm² | |
| Conductor cross section flexible min. PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 0.14 mm² PP-RJ-SCC-F 27030228 0.2 mm² PP-RJ-IDC-F 27030238 0.14 mm² | |
| Conductor cross section flexible max. PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 1.5 mm² PP-RJ-SCC-F 27030228 1.5 mm² PP-RJ-IDC-F 27030238 0.34 mm² | |
| Conductor cross section AWG min. PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 28 PP-RJ-SCC-F 27030228 26 PP-RJ-IDC-F 27030238 26 | |
| Conductor cross section AWG max. PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 16 PP-RJ-SCC-F 27030228 16 PP-RJ-IDC-F 27030238 22 | |
| Torque PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 0.22 Nm ... 0.25 Nm PP-RJ-SCC-F 27030228 PP-RJ-IDC-F 27030238 | |
| Stripping length PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 5 mm PP-RJ-SCC-F 27030228 8 mm PP-RJ-IDC-F 27030238 | |
| Wire diameter incl. insulation PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 PP-RJ-SCC-F 27030228 PP-RJ-IDC-F 27030238 1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request) | |
| Ambient conditions | |
| Ambient temperature (operation) -40°C ... 75°C | |
| Ambient temperature (storage/transport) -40°C ... 85°C | |
| Permissible humidity (operation) 10 % ... 95 % (non-condensing) | |
| Altitude 5000 m (For restrictions see manufacturer's declaration) / 2000 m (ATEX approval) | |
| Degree of protection IP20 (Manufacturer's declaration) | |
| General | |
| Electrical isolation FE // Ethernet | |
| Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU | |
| Net weight 124.2 g | |
| Housing material Plastic | |
| Color Gray | |
| MTTF PP-RJ-RJ-F 27030208 3281 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) PP-RJ-SC-F 27030218 3268 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) PP-RJ-SCC-F 27030228 3281 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) PP-RJ-IDC-F 27030238 3281 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) | |
| PP-RJ-RJ-F 27030208 1245 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25 % (5 days a week, 12 hours a day)) PP-RJ-SC-F 27030218 1238 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25 % (5 days a week, 12 hours a day)) PP-RJ-SCC-F 27030228 1245 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25 % (5 days a week, 12 hours a day)) PP-RJ-IDC-F 27030238 1245 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
| PP-RJ-RJ-F 27030208 472 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) PP-RJ-SC-F 27030218 468 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) PP-RJ-SCC-F 27030228 472 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) PP-RJ-IDC-F 27030238 472 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
| Degree of pollution 2 | |
| Overvoltage category II | |
| Conformance CE-compliant | |
| ATEX II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) | |
| UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 | |
| UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 / Class I, Div. 2, Groups A, B, C, D | |
| UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 | |
| Standards and Regulations | |
| Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU | |
| Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 | |
| Test result 10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g | |
| Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27 | |
| Test result 30g for 11 ms, three shocks in each spatial direction | |
| Type of test Continuous shock according to EN 60068-2-27/IEC 60068-2-27 | |
| Test result 10g for 16 ms, 1000 shocks in each spatial direction | |
| Standards/regulations EN 61000-4-2 | |
| Contact discharge ± 6 kV (Test Level 3) | |
| Indirect discharge ± 6 kV | |
| Standards/regulations EN 61000-4-3 | |
| Frequency range 80 MHz ... 3 GHz (Test Level 3) | |
| Standards/regulations EN 61000-4-4 | |
| Comments Criterion B | |
| Standards/regulations EN 61000-4-5 | |
| Signal ± 1 kV (Data line, asymmetrical) | |
| Standards/regulations EN 61000-6-4 / EN 61000-4-6 | |
| Frequency range 0.15 MHz ... 80 MHz | |
| Standards/regulations DIN EN 61643-21 | |
| Rated insulation voltage 85 V DC | |
| IEC test classification C2 | |
| Conformance CE-compliant | |
| ATEX II 3 G Ex nA nC IIC T4 Gc X | |
| UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 | |
| UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 / Class I, Div. 2, Groups A, B, C, D | |
| UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 | |
| Noxious gas test ISA-S71.04-1985 G3 Harsh Group A | |
| Function | |
| Designation Shield current monitoring | |
| Switch-on threshold ≥ 30 mA | |
| Local diagnostics Yellow LED | |
| Precision ± 5 % | |
| Response time 3 s | |
| Continuous shield current ≤ 1.5 A | |
| Power consumption 270 mW (Shield current monitoring) | |
| Impedance ≤ 1 Ω | |
| Voltage ≤ 10 V | |
| Dimensions | |
| Width 23.8 mm | |
| Height 101.3 mm | |
| Depth 86 mm | |
| Note | |
| Utilization restriction PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 1 PP-RJ-SCC-F 27030228 1 PP-RJ-IDC-F 27030238 1 | |
| Power supply | |
| Supply voltage range PP-RJ-RJ-F 27030208 36 V DC ... 52 V DC 10 % (via PoE (for shield current monitoring)) PP-RJ-SC-F 27030218 36 V DC ... 52 V DC 10 % (via PoE) PP-RJ-SCC-F 27030228 36 V DC ... 52 V DC 10 % (via PoE) PP-RJ-IDC-F 27030238 36 V DC ... 52 V DC 10 % (via PoE) | |
| 42 V DC ... 57 V DC (With UL approval) | |
| Approvals cULus Listed cUL Listed UL Listed | |
| Environmental Product Compliance | |
| China RoHS PP-RJ-RJ-F 27030208 Environmentally friendly use period: unlimited = EFUP-e PP-RJ-SC-F 27030218 Environmentally Friendly Use Period = 50 PP-RJ-SCC-F 27030228 Environmentally friendly use period: unlimited = EFUP-e PP-RJ-IDC-F 27030238 Environmentally friendly use period: unlimited = EFUP-e | |
| REACH SVHC PP-RJ-RJ-F 27030208 PP-RJ-SC-F 27030218 Lead 7439-92-1 PP-RJ-SCC-F 27030228 Lead 7439-92-1 PP-RJ-IDC-F 27030238 Lead 7439-92-1 |