IOLAN SDSC LDC Console Server

Telecommunication equipment engineers and project managers require a cost effective serial-to-Ethernet solution to monitor and manage
network equipment which is often installed in lights-out data centres, distant POP sites, and co-location facilities.IOLAN
SDSC LDC Console Serversare certified to meet harsh telecommunications environments addressed by the Telcordia
Network Equipment Building Standard (NEBS) Level 3 standard.

Telecommunication equipment engineers and project managers require a cost effective serial-to-Ethernet solution to monitor and manage
network equipment which is often installed in lights-out data centres, distant POP sites, and co-location facilities.IOLAN
SDSC LDC Console Serversare certified to meet harsh telecommunications environments addressed by the Telcordia
Network Equipment Building Standard (NEBS) Level 3 standard.

Specifications
Lifetime limited warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8517.62.0020 UNSPSC Code: 43222625 ECCN: 5A992
CCATS Number: G168387
CPU
Processor MPC8349E, 400 Mhz, 750 MIPS
Memory
RAM MB SDS8C LDC 64 SDS16C LDC 64 SDS32C LDC 64
Flash MB SDS8C LDC 16 SDS16C LDC 16 SDS32C LDC 16
Interface Ports
Number of Serial Ports SDS8C LDC 8 SDS16C LDC 16 SDS32C LDC 32
Serial Port Interface Software selectable RS232 / RS485 / RS422 DTE on RJ45 - RS485: full and half duplex
Sun / Solaris Sun / Oracle ‘Solaris' Safe - no break signal sent during power cycle causing costly server re-boots or downtime
Serial Port Speeds 50bps to 230Kbps with customizable baud rate support
Data Bits Configurable for 5,6,7 or 8-bit protocol support Use TruePort to transparently pass 9-bit serial data
Parity Odd, Even, Mark, Space, None
Flow Control Hardware, Software, Both, None
Serial Port Protection 15Kv Electrostatic Discharge Protection (ESD)
Local Console Ports RS232 on RJ45 with DB9 adapter (provided)
Network Dual 10/100/1000-base TX Ethernet RJ45 Software selectable Ethernet speed 10/100/1000, Auto Software selectable Half/Full/Auto duplex
Failsafe Alarm Relay 3A@24v DC. Normally open contacts closed by IOLAN when active and opened upon alarm condition or power failure
Power
Dual Power Supply 2 x Pluggable Terminal Blocks with screw terminals accommodating 28 - 12 AWG wire sizes
Nominal Input Voltage 24v DC / 48v DC
Input Voltage Range 18 - 72v DC
Current Consumption @ 18v DC (Amps) SDS8C LDC 0.4 SDS16C LDC 0.55 SDS32C LDC 0.85
Current Consumption @ 24v DC (Amps) SDS8C LDC 0.3 SDS16C LDC 0.4 SDS32C LDC 0.65
Current Consumption @ 48v DC (Amps) SDS8C LDC 0.2 SDS16C LDC 0.25 SDS32C LDC 0.35
Current Consumption @ 72v DC (Amps) SDS8C LDC 0.15 SDS16C LDC 0.18 SDS32C LDC 0.25
Typical Power Consumption (Watts) SDS8C LDC 11 SDS16C LDC 13 SDS32C LDC 18
Chassis Ground Grounding screw for a #10 ring terminal
Indicators
LEDs Power System Ready Network Link activity Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output (BTU/HR) SDS8C LDC 37.6 SDS16C LDC 44.4 SDS32C LDC 61.5
MTBF (Hours) SDS8C LDC 126,302 Hours SDS16C LDC 105,495 Hours SDS32C LDC 82,402 Hours
Calculation model based on MIL-HDBK-217-FN2 @ 30°C
Operating Temperature -40°C ambient for 16 hours and +70°C ambient for 16 hours without use of fans
Storage Temperature -40°C to 85°C, (-40°F to 185°F)
Humidity 5 to 95% (non condensing) for both storage and operation.
Case SECC Zinc plated sheet metal (1 mm)
Ingress Protection Rating IP30
Mounting 1U - 19' rack, front and rear mounting hardware included DIN Rail mounting kit optional
Product Weight and Dimensions
Weight SDS8C LDC 3.16 kg SDS16C LDC 3.18 kg SDS32C LDC 3.36 kg
Dimensions 1U Rack form factor - 26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in)
Packaging
Shipping Weight SDS8C LDC 3.96 kg SDS16C LDC 3.98 kg SDS32C LDC 4.16 kg
Shipping Dimensions 59 x 36 x 9 (cm), 23 x 14 x 3.5 (in)
Regulatory Approvals
Network Equipment Building Systems (NEBS) SR-3580 NEBS Level 3 GR-1089-CORE : NEBS EMI and Safety GR-1089-CORE per Verizon VZ.TPR.9205 and ATT-TP-76200 GR-63-CORE: NEBS Physical Protection GR-63-CORE / ANSI T1.319 per Verizon VZ.TPR.9305 and ATT-TP-76200
Emissions Power Line conducted: IEC 61850-3 Sec 5.8 CISPR 32 / EN 55032 EN55011 (CISPR11) Telecom Line conducted: IEC 61000-6-4 Radiated: IEC 61850-3 Sec 5.8 EN61000-3-2 : 2010 Limits for Harmonic Current Emissions EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker
Immunity IEC 61850-3 (substations) IEEE 1613 (substations) (C37.90.x) Applies to all ports, signal and power connections ESD: IEC61000-4-2, 8Kv Contact / 15Kv Air Radiated RFI: IEC61000-4-3, 20 V/m (80M-1G) Fast Transients / Burst: IEC61000-4-4, 4Kv Mains , I/O Surge : IEC61000-4-5 4Kv AC line to Gnd, 2Kv AC Line to Line, 2Kv DC line to Gnd, 1 Kv DC Line to Line, RS232 = balanced, ethernet = unbalanced Conducted RF: IEC61000-4-6, 10 Vrms Magnetic Field: IEC61000-4-8, 100 A/m, 1000 A/m (1 sec) Dips and Interrupts: IEC61000-4-11, Criteria A/B/C Oscillatory: EN61000-4-12, 2.5Kv common and differential mode Low Frequency conducted: EN61000-4-16, 30V 60s, 300V 1s,15Hz-150KHz @ level 3
Safety UL/EN/IEC 62368-1 CAN/CSA C22.2 No. 62368-1 IEC 60950-1(ed 2); am1, am2 and EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 NEBS GR-1089-CORE ISSUE 4 (Level 3, Type 2 and Type 4)
X