Telecommunication equipment engineers and project managers require a cost effective serial-to-Ethernet solution to monitor and manage
network equipment which is often installed in lights-out data centres, distant POP sites, and co-location facilities.IOLAN
SDSC LDC Console Serversare certified to meet harsh telecommunications environments addressed by the Telcordia
Network Equipment Building Standard (NEBS) Level 3 standard.
Telecommunication equipment engineers and project managers require a cost effective serial-to-Ethernet solution to monitor and manage
network equipment which is often installed in lights-out data centres, distant POP sites, and co-location facilities.IOLAN
SDSC LDC Console Serversare certified to meet harsh telecommunications environments addressed by the Telcordia
Network Equipment Building Standard (NEBS) Level 3 standard.
| Specifications | |
| Lifetime limited warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8517.62.0020 UNSPSC Code: 43222625 ECCN: 5A992 | |
| CCATS Number: G168387 | |
| CPU | |
| Processor MPC8349E, 400 Mhz, 750 MIPS | |
| Memory | |
| RAM MB SDS8C LDC 64 SDS16C LDC 64 SDS32C LDC 64 | |
| Flash MB SDS8C LDC 16 SDS16C LDC 16 SDS32C LDC 16 | |
| Interface Ports | |
| Number of Serial Ports SDS8C LDC 8 SDS16C LDC 16 SDS32C LDC 32 | |
| Serial Port Interface Software selectable RS232 / RS485 / RS422 DTE on RJ45 - RS485: full and half duplex | |
| Sun / Solaris Sun / Oracle ‘Solaris' Safe - no break signal sent during power cycle causing costly server re-boots or downtime | |
| Serial Port Speeds 50bps to 230Kbps with customizable baud rate support | |
| Data Bits Configurable for 5,6,7 or 8-bit protocol support Use TruePort to transparently pass 9-bit serial data | |
| Parity Odd, Even, Mark, Space, None | |
| Flow Control Hardware, Software, Both, None | |
| Serial Port Protection 15Kv Electrostatic Discharge Protection (ESD) | |
| Local Console Ports RS232 on RJ45 with DB9 adapter (provided) | |
| Network Dual 10/100/1000-base TX Ethernet RJ45 Software selectable Ethernet speed 10/100/1000, Auto Software selectable Half/Full/Auto duplex | |
| Failsafe Alarm Relay 3A@24v DC. Normally open contacts closed by IOLAN when active and opened upon alarm condition or power failure | |
| Power | |
| Dual Power Supply 2 x Pluggable Terminal Blocks with screw terminals accommodating 28 - 12 AWG wire sizes | |
| Nominal Input Voltage 24v DC / 48v DC | |
| Input Voltage Range 18 - 72v DC | |
| Current Consumption @ 18v DC (Amps) SDS8C LDC 0.4 SDS16C LDC 0.55 SDS32C LDC 0.85 | |
| Current Consumption @ 24v DC (Amps) SDS8C LDC 0.3 SDS16C LDC 0.4 SDS32C LDC 0.65 | |
| Current Consumption @ 48v DC (Amps) SDS8C LDC 0.2 SDS16C LDC 0.25 SDS32C LDC 0.35 | |
| Current Consumption @ 72v DC (Amps) SDS8C LDC 0.15 SDS16C LDC 0.18 SDS32C LDC 0.25 | |
| Typical Power Consumption (Watts) SDS8C LDC 11 SDS16C LDC 13 SDS32C LDC 18 | |
| Chassis Ground Grounding screw for a #10 ring terminal | |
| Indicators | |
| LEDs Power System Ready Network Link activity Serial: Transmit and Receive data per port | |
| Environmental Specifications | |
| Heat Output (BTU/HR) SDS8C LDC 37.6 SDS16C LDC 44.4 SDS32C LDC 61.5 | |
| MTBF (Hours) SDS8C LDC 126,302 Hours SDS16C LDC 105,495 Hours SDS32C LDC 82,402 Hours | |
| Calculation model based on MIL-HDBK-217-FN2 @ 30°C | |
| Operating Temperature -40°C ambient for 16 hours and +70°C ambient for 16 hours without use of fans | |
| Storage Temperature -40°C to 85°C, (-40°F to 185°F) | |
| Humidity 5 to 95% (non condensing) for both storage and operation. | |
| Case SECC Zinc plated sheet metal (1 mm) | |
| Ingress Protection Rating IP30 | |
| Mounting 1U - 19' rack, front and rear mounting hardware included DIN Rail mounting kit optional | |
| Product Weight and Dimensions | |
| Weight SDS8C LDC 3.16 kg SDS16C LDC 3.18 kg SDS32C LDC 3.36 kg | |
| Dimensions 1U Rack form factor - 26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in) | |
| Packaging | |
| Shipping Weight SDS8C LDC 3.96 kg SDS16C LDC 3.98 kg SDS32C LDC 4.16 kg | |
| Shipping Dimensions 59 x 36 x 9 (cm), 23 x 14 x 3.5 (in) | |
| Regulatory Approvals | |
| Network Equipment Building Systems (NEBS) SR-3580 NEBS Level 3 GR-1089-CORE : NEBS EMI and Safety GR-1089-CORE per Verizon VZ.TPR.9205 and ATT-TP-76200 GR-63-CORE: NEBS Physical Protection GR-63-CORE / ANSI T1.319 per Verizon VZ.TPR.9305 and ATT-TP-76200 | |
| Emissions Power Line conducted: IEC 61850-3 Sec 5.8 CISPR 32 / EN 55032 EN55011 (CISPR11) Telecom Line conducted: IEC 61000-6-4 Radiated: IEC 61850-3 Sec 5.8 EN61000-3-2 : 2010 Limits for Harmonic Current Emissions EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker | |
| Immunity IEC 61850-3 (substations) IEEE 1613 (substations) (C37.90.x) Applies to all ports, signal and power connections ESD: IEC61000-4-2, 8Kv Contact / 15Kv Air Radiated RFI: IEC61000-4-3, 20 V/m (80M-1G) Fast Transients / Burst: IEC61000-4-4, 4Kv Mains , I/O Surge : IEC61000-4-5 4Kv AC line to Gnd, 2Kv AC Line to Line, 2Kv DC line to Gnd, 1 Kv DC Line to Line, RS232 = balanced, ethernet = unbalanced Conducted RF: IEC61000-4-6, 10 Vrms Magnetic Field: IEC61000-4-8, 100 A/m, 1000 A/m (1 sec) Dips and Interrupts: IEC61000-4-11, Criteria A/B/C Oscillatory: EN61000-4-12, 2.5Kv common and differential mode Low Frequency conducted: EN61000-4-16, 30V 60s, 300V 1s,15Hz-150KHz @ level 3 | |
| Safety UL/EN/IEC 62368-1 CAN/CSA C22.2 No. 62368-1 IEC 60950-1(ed 2); am1, am2 and EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 NEBS GR-1089-CORE ISSUE 4 (Level 3, Type 2 and Type 4) |