INJ 1100-T DIN Rail PoE Injectors with electrical isolation

INJ 1100-T PoE Injectorsare DIN Rail mounted single port,PoE mid-span injectors. They act as an intermediary devices between a non-PoE switch and a PoE device to injectfully compliantpower over the Ethernet cable. With electrical isolation of the internal power supply, the INJ-1100-T units are also protected against short circuits on the PoE side.

Generatingup to 60 Watts, the INJ 1100-T provides electrical power to remotePD access points,pan-tilt and zoom (PTZ) camerasandvideo-phones. It complies with theIEEE802.3bt Hi-PoE (60W of power)orIEEE 802.3at PoE+ (30W of power)standards and is also backward compatible with IEEE802.3af PoE (15.4W of power).Learn more about PoE.

With the INJ 1100-T, there is no need to buy an expensive PoE switch or install electrical wiring and outlets in hard to reach locations. Just use and open port on an existing non-PoE switch to save time and money by sending power and data over the same cable.

INJ 1100-T PoE Injectorsare DIN Rail mounted single port,PoE mid-span injectors. They act as an intermediary devices between a non-PoE switch and a PoE device to injectfully compliantpower over the Ethernet cable. With electrical isolation of the internal power supply, the INJ-1100-T units are also protected against short circuits on the PoE side.

Generatingup to 60 Watts, the INJ 1100-T provides electrical power to remotePD access points,pan-tilt and zoom (PTZ) camerasandvideo-phones. It complies with theIEEE802.3bt Hi-PoE (60W of power)orIEEE 802.3at PoE+ (30W of power)standards and is also backward compatible with IEEE802.3af PoE (15.4W of power).Learn more about PoE.

With the INJ 1100-T, there is no need to buy an expensive PoE switch or install electrical wiring and outlets in hard to reach locations. Just use and open port on an existing non-PoE switch to save time and money by sending power and data over the same cable.

  • DIN Rail Enclosure
  • Power Over Ethernet (PSE)
  • Electrical isolation of the internal power supply unit
  • Potential Separation
  • On-board PoE Power Controller
  • Advanced Power Management
Specifications
1 Year Return to Factory Warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8517.62.0020 UNSPSC Code: 43223300 ECCN: 5A991
Serial interface
Interface 1 Ethernet
Connection method RJ45 socket
Transmission length 100 m (including patch cables)
Power Connector 1:1
Basic functions PSE/Midspan, compliant with IEEE 802.3af, at
Serial transmission speed 10/100/1000 Mbps
Output nominal voltage 54 V DC (PoE)
Output power INJ 1100-T 27030098 30 W INJ 1110-T 27030098 60 W
Maximum output power INJ 1100-T 27030098 40 W INJ 1110-T 27030098 75 W
Interface 2 Ethernet
Connection method RJ45 CAT5e
Ambient conditions
Ambient temperature (storage/transport) -40°C ... 85°C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
General
Electrical isolation VCC // FE // PoE
Test voltage data interface/power supply 1.5 kV AC (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Mounting position vertical
Net weight 324.72 g
Housing material Plastic
Color Gray
MTTF (SN 29500 standard, temperature 25°C , operating cycle 21 % (5 days a week, 8 hours a day) ) INJ 1100-T 27030098 2342 Years INJ 1110-T 27030098 3062 Years
MTTF (SN 29500 standard, temperature 40°C , operating cycle 34.25 % (5 days a week, 12 hours a day) ) INJ 1100-T 27030098 1167 Years INJ 1110-T 27030098 1397 Years
MTTF (SN 29500 standard, temperature 40°C , operating cycle 100 % (7 days a week, 24 hours a day) ) INJ 1100-T 27030098 467 Years INJ 1110-T 27030098 558 Years
Conformance CE-compliant
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 Class I, Division 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Standards and Regulations
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result 10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g
Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result 30g for 11 ms, three shocks in each spatial direction
Type of test Continuous shock according to EN 60068-2-27/IEC 60068-2-27
Test result 10g for 16 ms, 1000 shocks in each spatial direction
Standards/regulations EN 61000-4-2
Contact discharge ± 6 kV (Test Level 3)
Indirect discharge INJ 1100-T 27030098 ± 6 kV INJ 1110-T 27030098
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 3 GHz (Test Level 3)
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal ± 1 kV (Data line, asymmetrical) ± 2 kV (I/O cable on field side only, asymmetric)
Standards/regulations EN 61000-6-4 EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Conformance CE-compliant
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 Class I, Division 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Noxious gas test ISA-S71.04-1985 G3 Harsh Group A
Dimensions
Width 30.2 mm
Height 130 mm
Depth 120 mm
Note
Utilization restriction 1
Power supply
Nominal supply voltage 24 V DC 48 V DC
Supply voltage range 18 V DC ... 57 V DC
Max. current consumption INJ 1100-T 27030098 2.1 A 1.4 A (24 V DC) 0.7 A (48 V DC) INJ 1110-T 27030098 4.2 A 2.73 A (24 V DC) 1.34 A (48 V DC)
Power consumption ≤ 75 W
Protective circuit Reverse polarity protection
Conductor cross section flexible max. 4.00 mm²
Conductor cross section flexible min. 0.75 mm²
Conductor cross section solid max. 4.00 mm²
Conductor cross section solid min. 0.75 mm²
Conductor cross section AWG max. 12
Conductor cross section AWG min. 20
Environmental Product Compliance
REACH SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
X