PerleeXP-S1110PE PoE+ Gigabit Ethernet Extenderstransparently extend Ethernet beyond the general limits of 328ft / 100mwhile providing Power over Ethernet (PoE+)to standards-based compliant devices such as IP cameras, VoIP phones and wireless access points.
This technology enables users to transparentlyextend up to four 10/100/1000 Power over Ethernet connectionsacross copper wiring. Use single twisted pair (CAT5/6/7), coax or any existing copper wiring previously used in alarm circuits, E1/T1 circuits, RS-232, RS-422, RS-485, CCTV and CATV applications.
These PoE+ Ethernet Extenders areclassified as Power Sourcing Equipment (PSE). While using standard UTP cables that carry Ethernet data, Perle eXP-S1110PE PoE Ethernet Extendersprovide up to 30 watts of powerto Powered Devices (PDs).Learn more about PoE.
PerleeXP-S1110PE PoE+ Gigabit Ethernet Extenderstransparently extend Ethernet beyond the general limits of 328ft / 100mwhile providing Power over Ethernet (PoE+)to standards-based compliant devices such as IP cameras, VoIP phones and wireless access points.
This technology enables users to transparentlyextend up to four 10/100/1000 Power over Ethernet connectionsacross copper wiring. Use single twisted pair (CAT5/6/7), coax or any existing copper wiring previously used in alarm circuits, E1/T1 circuits, RS-232, RS-422, RS-485, CCTV and CATV applications.
These PoE+ Ethernet Extenders areclassified as Power Sourcing Equipment (PSE). While using standard UTP cables that carry Ethernet data, Perle eXP-S1110PE PoE Ethernet Extendersprovide up to 30 watts of powerto Powered Devices (PDs).Learn more about PoE.
| High Speed Asymmetric | |||
| Reach (Distance) | VDSL Rate (Mbps) | ||
| feet | meters | Downstream | Upstream |
| 500 | 152 | 101 | 92 |
| 1000 | 305 | 101 | 63 |
| 1500 | 457 | 90 | 38 |
| 2000 | 610 | 62 | 24 |
| 2500 | 762 | 55 | 10 |
| 3000 | 914 | 42 | 5 |
| 3500 | 1000 | 35 | 3 |
| High Speed Symmetric | |||
| Reach (Distance) | VDSL Rate (Mbps) | ||
| feet | meters | Downstream | Upstream |
| 500 | 152 | 101 | 101 |
| 1000 | 305 | 85 | 101 |
| 1500 | 457 | 62 | 47 |
| 2000 | 610 | 60 | 29 |
| 2500 | 762 | 44 | 14 |
| 3000 | 914 | 30 | 7 |
| 3500 | 1000 | 29 | 4 |
| Long Reach Symmetric | |||
| Reach (Distance) | VDSL Rate (Mbps) | ||
| feet | meters | Downstream | Upstream |
| 500 | 152 | 53 | 44 |
| 1000 | 305 | 53 | 43 |
| 2500 | 762 | 39 | 18 |
| 4000 | 1219 | 25 | 4 |
| 5500 | 1676 | 17 | 1.9 |
| 7000 | 2134 | 8 | 2.3 |
| 7500 | 2286 | 7 | 2.2 |
| 8000 | 2438 | 5 | 2.2 |
| Long Reach Asymmetric | |||
| Reach (Distance) | VDSL Rate (Mbps) | ||
| feet | meters | Downstream | Upstream |
| 500 | 152 | 78 | 16 |
| 1000 | 305 | 78 | 16 |
| 2500 | 762 | 55 | 10 |
| 4000 | 1219 | 31 | 0.8 |
| 5500 | 1676 | 20 | 0.6 |
| 7000 | 2134 | 11 | 0.6 |
| 7500 | 2286 | 10 | 0.6 |
| 8000 | 2438 | 8 | 0.6 |
| Specifications | |
| Lifetime limited warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8517.62.0020 UNSPSC Code: 43222608 ECCN: 5A991 | |
| Power | |
| Unit Powered by Local power adapter | |
| Provides Power to E thernet | |
| Power adapter connector Barrel or terminal block | |
| Input Voltage Range from adapter 46V to 57 | |
| Input Voltage Range from VDSL (parasitic) 24 to 57 | |
| Universal AC Adapter 56vDC, 75 watt adapter included | |
| Power Connectors 5.5mm x 9.5mm x 2.1mm barrel socket and 2 pin terminal Block | |
| Ethernet | |
| 10/100/1000Base-T Port(s) eXP-1S1110PE 1 port RJ45 Shielded eXP-4S1110PE 4 port RJ45 Shielded | |
| Auto-MDIX Auto-MDIX enables proper operation with either straight-through or crossover cabling | |
| Distance Distance up to 100 meters (328 feet) as per IEEE 802.3 | |
| Maximum Frame Size Type 2 PSE (PoE+) IEEE 802.3at | |
| PoE PSE Maximum Power (Watts) Refer to the Power Reach Installation Planning Guide | |
| PoE PSE RJ45 Cable Pinout Alternative A (default) on all ports: Pins 3,6 Neg, Pins 1,2 Pos Alternative B: selectable on port #1: Pins 7,8 Neg, Pins 4,5 Pos Legacy Cisco Pre-Standard: selectable on port #1: Legacy Cisco Pre-Standard: selectable on port #1: | |
| VDSL – Interlink | |
| RJ45, BNC, Terminal Block Ethernet Extenders must be connected in pairs using unconditioned wire. Circuits that run through signal equalization equipment are not permitted. TIP and RING are polarity insensitive. Surge suppression of 400 volts between TIP and RING. Choice of RJ45, BNC or terminal block models for VDSL link connector: RJ45 – RING pin 4, TIP pin 5 (TIA 568 A/B) BNC – Coaxial 50 and 75 ohm cable with BNC connector Terminal Block – 2 position screw connectors for use with twisted pair telephone, alarm or serial cabling between 19 (0.9 mm) and 26 AWG (0.44 mm). | |
| VDSL2 Line Rate/Reach Actual distance and rates experienced will depend on condition and gauge of wire used. This Rate/Reach table applies to 24 AWG (0.5 MM) twisted pair wiring on RJ45 (RJ) and terminal block (TB) models High Speed Asymmetric Reach (Distance) VDSL Rate (Mbps) feet meters Downstream Upstream 500 152 101 92 1000 305 101 63 1500 457 90 38 2000 610 62 24 2500 762 55 10 3000 914 42 5 3500 1000 35 3 High Speed Symmetric Reach (Distance) VDSL Rate (Mbps) feet meters Downstream Upstream 500 152 101 101 1000 305 85 101 1500 457 62 47 2000 610 60 29 2500 762 44 14 3000 914 30 7 3500 1000 29 4 Long Reach Symmetric Reach (Distance) VDSL Rate (Mbps) feet meters Downstream Upstream 500 152 53 44 1000 305 53 43 2500 762 39 18 4000 1219 25 4 5500 1676 17 1.9 7000 2134 8 2.3 7500 2286 7 2.2 8000 2438 5 2.2 Long Reach Asymmetric Reach (Distance) VDSL Rate (Mbps) feet meters Downstream Upstream 500 152 78 16 1000 305 78 16 2500 762 55 10 4000 1219 31 0.8 5500 1676 20 0.6 7000 2134 11 0.6 7500 2286 10 0.6 8000 2438 8 0.6 | |
| Power Budget The amount of available power at the PoE PD is dependent on the scenario planned. Refer to the Power Reach Installation Planning Guide | |
| Indicators | |
| Power / TST This green LED is turned on when power is applied to the Ethernet Extender. Otherwise it is off. The LED will blink when in Loopback test mode. | |
| CO - Local Ethernet Extender is operating in CO VDSL mode | |
| CPE - remote Ethernet Extender is operating in CPE VDSL mode | |
| ILNK Indicates Link Status and activity on the Interlink (VDSL) port | |
| ETH Indicates link status and activity on Ethernet port(s). | |
| PSE Status This LED will signify the status of the PSE function. Using multi-color and blinking the unit will show the following status for the PSE; GREEN — Solid: The PSE has successfully detected a compliant PD and is applying power over the UTP (for legacy pin out simply show active power when applied) YELLOW — Solid: The PSE is not active. This means the PSE has been configured to provide power, but the PD is : Not connected Has not detected a compliant PD and is not applying power PSE has turned off power for Reset function OFF — PSE function switch disabled RED — Blinking: Error Conditions Capacitance too High — 1 blink Resistance too Low or short circuit — 2 blinks Resistance too high or open circuit — 3 blinks | |
| Switches | |
| Access Switch settings are accessible through a side opening in the chassis | |
| Rate/Reach Two switches enable the user to select the right balance between speed and distance for their environment. | |
| Signal to Noise Ratio Selectable Signal to Noise Ratio (SNR) of 6dB or 9dB. The higher SNR number provides better impulse noise protection but lowers performance. | |
| Auto-Negotiation (802.3u) control on Port 1 Enabled (Default) - The Ethernet Extender uses 802.3u Auto-negotiation on the 10/100/1000Base-T interface. It is set to advertise full duplex. Disabled - The Ethernet Extender sets the port according to the position of the speed and duplex switches. | |
| Force Ethernet Speed on Port 1 When Auto-Negotiation switch is disabled, a fixed speed can be forced on port 1 to 100 (Default) or 10 | |
| Force Ethernet Duplex on Port 1 When Auto-Negotiation switch is disabled, Full or half Duplex can be forced on port 1 to Full (Default) or Half | |
| Link Mode* Standard (Default) – The 10/100/1000Base-T link remains active independent of the state of the Ethernet link on its remote peer. Link Pass-Through - state of the 10/100/1000Base-T Ethernet connection is “passed through” or propagated across the VDSL link to the 10/100/1000Base-T Ethernet link on its remote Ethernet Extender peer | |
| Interlink Fault Feedback* Enabled – A loss of VDSL link will drop the 10/100/1000 Ethernet port on each end until the link recovers Disabled (Default) - The state of the VDSL link is not propagated to the 10/100/1000Base-T port | |
| Loopback Enabled – The VDSL interlink will perform a loopback function, retransmitting all received Ethernet frames back to its remote peer. Disabled (Default - Up) | |
| PD Reset (Port 1) When enabled (down), the Ethernet Extender will upon loss of link on the VDSL Interlink port, turn off PSE output power to the PD device for 2 seconds then turn the power back on. The power remains on until the VDSL link transitions from up to down again. When PD Power Reset is disabled (default), loss of VDSL link has no effect on power supplied to the PD. | |
| Environmental Specifications | |
| Operating Temperature 0°C to 50°C (-32°F to 122°F) | |
| Storage Temperature minimum range of -25°C to 70°C (-13°F to 158°F) | |
| Operating Humidity 5% to 90% non-condensing | |
| Storage Humidity 5% to 95% non-condensing | |
| Operating Altitude Up to 3,048 meters (10,000 feet) | |
| Current mA eXP-1S1110PE 114 @ 56vdc eXP-4S1110PE 163 @ 56vdc | |
| Unit Power Consumption watts eXP-1S1110PE 6.4 eXP-4S1110PE 9.1 | |
| Heat Output (BTU/HR) eXP-1S1110PE 21.84 eXP-4S1110PE 31.05 | |
| MTBF with power adapter (Hours)** eXP-1S1110PE 75,029 Hours eXP-4S1110PE 72,416 Hours | |
| MTBF without power adapter (Hours)** eXP-1S1110PE 300,472 Hours eXP-4S1110PE 262,530 Hours | |
| *MTBF Calculation model based on MIL-HDBK-217-FN2 @ 30°C | |
| Mounting | |
| Wall/Desk Standard | |
| Din Rail Kit Optional | |
| Rack Mount Kit Optional | |
| Product Weight and Dimensions | |
| Weight eXP-1S1110PE 0.58 Kg, 1.3 lbs eXP-4S1110PE 0.61Kg, 1.34 lbs | |
| Dimensions 163 x 116 x 37 mm, 6.4 x 4.6 x 1.46 inches | |
| Packaging | |
| Shipping Weight eXP-1S1110PE 1.27 Kg, 2.8 lbs eXP-4S1110PE 1.3 Kg, 2.86 lbs | |
| Shipping Dimensions 20 x 30 x 7 cm, 7.9 x 11.8 x 2.8 inches | |
| Regulatory Approvals | |
| Emissions CISPR 32 / EN 55032 IEC/EN 61000-3-2 IEC/EN 61000-3-3 | |
| Immunity CISPR 35 / EN 55035 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-11 | |
| Electrical Safety UL/EN/IEC 62368-1 CAN/CSA C22.2 No. 62368-1 UL 60950-1 IEC 60950-1(ed 2); am1, am2 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 CSA C22.2 No. 60950-1 |