Perle’sEthernet I/Otechnology (IOLAN DS I/O Device Servers) enables comprehensive access and control of remote digital I/O, analog I/O, pulse I/O, relays and temperature sensors as well as connections of remote serial equipment on any IP network. The IOLAN DS I/O has the ability to monitor environmental alarms, intrusion detection, relay contact closures and equipment failure. Through remote operator or application control, opening and closing of integrated relay contacts or activation of digital output signals can be incorporated into any response of a critical event.
Management, Monitoring and Control of High-Value Distributed I/O AssetsIdeal for
Why IOLAN DS I/O Device Servers are the preferred choice:
Perle’sEthernet I/Otechnology (IOLAN DS I/O Device Servers) enables comprehensive access and control of remote digital I/O, analog I/O, pulse I/O, relays and temperature sensors as well as connections of remote serial equipment on any IP network. The IOLAN DS I/O has the ability to monitor environmental alarms, intrusion detection, relay contact closures and equipment failure. Through remote operator or application control, opening and closing of integrated relay contacts or activation of digital output signals can be incorporated into any response of a critical event.
Management, Monitoring and Control of High-Value Distributed I/O AssetsIdeal for
Why IOLAN DS I/O Device Servers are the preferred choice:
| Specifications | |
| Lifetime limited warranty Reach, RoHS and WEEE Compliant HTSUS Number: 8471.80.1000 UNSPSC Code: 43222625 ECCN: 5A991 | |
| CPU | |
| Main Processor MPC852T, 66 Mhz, 87 MIPS | |
| Memory | |
| RAM 16 MB | |
| Flash 4 MB | |
| I/O Processor | |
| ATMEG48, 16 MIPS | |
| Network/Ethernet | |
| 1 x 10/100Mb RJ45 1.5 KV magnetic isolation | |
| I/O Connectors | |
| Removable terminal blocks | |
| Digital I/O | |
| 2 or 4 channels depending on model software selectable as inputs or outputs optical isolation of 2000V rms | |
| Digital Input | |
| Dry Contact Logic 0 = open. Logic 1= close to GND | |
| Wet Contact Logic 0 = 0-3VDC, Logic 1= 10VDC-30VDC | |
| Digital Output | |
| Open collector to 30VDC (source, sink or both) 200 mA max load Digital out (DO) or pulse mode | |
| Relay | |
| Form C type SPDT | |
| Contact rating 1A@30VDC, 0.5A @AC: 120VAC | |
| Breakdown voltage 500 VAC (50/60 Hz) | |
| Relay on time 7 msec; Relay off time: 3 msec. | |
| Total switching time 10 msec. | |
| Insulation resistance 1000 MW minimum at 500 VDC | |
| Analog Input | |
| Channels 4 differential | |
| 16-bit resolution | |
| Input range ±150 mVDC, ±500 mVDC, ±1 VDC, ±5 VDC, ±10 VDC, 0-20 mA, 4-20 mA | |
| Optical Isolation 3000 VDC | |
| Fault and overvoltage protection up to ±35 V | |
| Sampling rate 10 samples/sec. | |
| Input impedance 20 M Ohm | |
| Accuracy ±0.1% or better | |
| Zero drift ±5 µV/° C | |
| Span drift ±25 ppm/° C | |
| CMR @ 50/60 Hz 90 dB min | |
| Thermocouple Input | |
| Types J, K, T, E, R, S, B | |
| Isolation voltage 2000 VDC | |
| Sampling rate 10 samples/sec. | |
| Accuracy ±0.15% or better | |
| Zero drift ±5 µV/° C | |
| Span drift ±25 ppm/° C | |
| CMR @ 50/60 Hz 130 dB | |
| RTD (Resistance Temperature Detector) | |
| Channels 4 differential inputs | |
| Input type PT100, PT1000, Ni 518 | |
| Optical Isolation 2000 VDC | |
| Sampling rate 10 samples/sec | |
| Accuracy ±0.05% or better | |
| Zero drift ±2.5 µV/° C | |
| Span drift ±25 ppm/° C | |
| CMR @ 50/60 Hz 130 dB | |
| Protocols | |
| IPV6, IPV4, TCP/IP, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, Telnet, raw, reverse Telnet, MODBus/TCP, RCP, WINS, HTTP, SNMPV3* | |
| Management | |
| Via Web browser | |
| Perle DeviceManager software to manage single or multiple device servers | |
| CLI – Telnet or shared console port | |
| Menu | |
| SNMP, MIB II, Perle MIB, read and write capabilities | |
| SYSLOG | |
| Easy Configuration Wizard | |
| Failsafe mode Default outputs if loss of communication occurs | |
| Set a personalized factory default for IOLANs | |
| Serial Port | |
| Software selectable EIA/RS-232/422/485 | |
| DB9M connector | |
| Full modem and hardware flow control on RS-232 | |
| 50bps to 230Kbps for EIA-232 | |
| Customizable baud rate support for unique speed requirements | |
| up to 230Kbps for EIA-422/485 | |
| SUN Break Safe | |
| Full bidirectional modem support | |
| 15Kv ESD protection on all signals | |
| EIA 232 full duplex | |
| EIA 422 full duplex | |
| EIA 485 4 wire, full duplex | |
| EIA 485 2 wire, half duplex, with echo | |
| EIA 485 2 wire, half duplex, without echo | |
| Indicators | |
| Power/Ready | |
| Network Link activity | |
| Serial Transmit and Receive data LEDs | |
| Dimensions, Weight | |
| Dimensions (L x W x H): 12.7 x 9.2 x 4.5 (cm) | |
| Weight 0.5 kg | |
| Power | |
| 9-30V DC on terminal blocks. | |
| Optional AC adapters available from Perle | |
| p/n 04031154 (USA), 04031151 (UK), 04031152 (EU) | |
| TruePort: Fixed TTY/COM port emulation software. | |
| TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX. Perle supports the most comprehensive driver set in the industry. For a complete list of all the latest drivers click here . | |
| Storage Temperature -40°C to +66°C (-40°F to +150°F) | |
| Chassis Metal with an IP30 ingress protection rating | |
| Approvals | |
| FCC Part 15A, CE, UL/EN/IEC 62368-1 (previously 60950-1), CAN/CSA C22.2 No. 62368-1, CISPR 32 / EN 55032, CISPR 35 / EN 55035, CFR 47, ICES-003 | |
| Line Art | |
| IOLAN DS1 D4 – 4 Digital I/O and 1 RS-232/422/485 Serial Port IOLAN DS1 D2R2 – 2 Digital I/O, 2 Relay outputs and 1 RS-232/422/485 Serial Port IOLAN DS1 A4 – 4 Analog Inputs and 1 RS-232/422/485 Serial Port IOLAN DS1 T4 – 4 Thermocouple/RTD sensor inputs and 1 RS-232/422/485 Serial Port IOLAN DS1 A4R2 – 4 Analog inputs and 2 Relay Outputs and 1 RS-232/422/485 Serial Port IOLAN DS1 A4D2 – 4 Analog inputs and 2 Digital I/O and 1 RS-232/422/485 Serial Port |